Sign In | Join Free | My burrillandco.com
Home > Huawei DWDM >

OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS

Uonel Co.Limtied
Contact Now
    Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
     
    Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
    • Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
    • Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
    • Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
    • Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers
    • Buy cheap OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS from wholesalers

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS

    Ask Lasest Price
    Model Number : TN12LSC
    Brand Name : Huawei
    Supply Ability : 200 Piece/Pieces per Week
    Price : Negotiable
    Certification : CE FCC RoHS
    Delivery Time : 7-15 days
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    • Product Details
    • Company Profile

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS

    Contact Us

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS


    Functions and Features

    The LSC board is mainly used to achieve wavelength tunable and to provide OTN interfaces and ESC.

    For detailed functions and features, see Table 1 and Table 2.

    Table 1 Functions and features of the LSC board
    Function and FeatureDescription
    Basic function

    LSC converts signal as follows:

    • 1x 100GE/OTU4<->1x OTU4
    Client-side service type

    100GE: Ethernet service at a rate of 103.125 Gbit/s.

    OTU4: OTN service at a rate of 111.81 Gbit/s

    OTN function
    • Provides the OTU4 interface on WDM-side.
    • Supports the OTN frame format and overhead processing compliant with ITU-T G.709.
    • ODU4 layer:
      • When the client-side service type is 100GE, the board supports the PM function.
      • When the client-side service type is OTU4, the board supports the PM and TCM functions, PM and TCM non-intrusive monitoring functions.
    • OTU4 layer: supports the SM function.
    WDM specification

    Supports ITU-T G.694.1-compliant DWDM specifications.

    Tunable wavelength function

    The TN18LSC board can tune the optical signal output on the WDM side within the range of 96 wavelengths in extended C-band with the channel spacing of 50 GHz , and other boards can tune the optical signal output on the WDM side within the range of 80 wavelengths in the C-band with the channel spacing of 50 GHz.

    ESC function

    Supported

    NOTE:
    When the TN12LSC board is provisioned with the OTU4 service on the client side, the board does not support ESC function on the client side.
    PRBS test function

    When the client-side service type is OTU4, the PRBS function is supported on the client side.

    When the client-side service type is 100GE or OTU4, the PRBS function is also supported on the WDM side.

    LPT functionNot supported
    FEC coding

    On the client side:

    Supports ITU-T G.709-compliant forward error correction (FEC) on the client side, only when the client side service type is OTU4.

    On the WDM side:

    The TN12LSC/TN13LSC board supports HFEC and SDFEC.

    The TN15LSC board supports HFEC and SDFEC2.

    The TN17LSC board supports SDFEC2.

    The TN18LSC board supports SDFEC2 and HFEC PLUS.

    NOTE:
    Boards that use different FEC modes cannot interconnect with each other.
    Alarms and performance events monitoring
    • Monitors BIP8 bytes (Bursty mode) to help locate line failures.
    • Monitors OTN alarms and performance events.
    • Monitors parameters such as the bias current, temperature, and optical power of the laser.
    • Supports the remote monitoring (RMON) of Ethernet services.

    • Supports the monitoring of CD and PMD performance.
    NOTE:
    Only the TN12LSC board does not support the monitoring of BIP8 bytes on the client side.
    Regeneration board
    The WDM-side signals of an LSC board can be regenerated using the N401, N402, U401, LTX, NS4, TN18LSC board of the same type. For example,
    • The type of the TN12LSCT01 board is T01, and the WDM-side signals of the TN12LSCT01 board can be regenerated using the N401, N402, LTX, NS4, TN18LSC board of the T01 type, such as TNV1N401T01, TNV2N402T01, TNV2N401T01, , TN12LTXT01, TN54NS4T01, TNV2U401T01, TN57NS4T01, TN58NS4T01. TN11LTXT01, TN18LSC.
    ALS function

    Supports the ALS function on the client side when client services are non-OTN services.

    Test frameSupported only when the client-side service type is 100GE.
    Latency measurement

    The TN13LSC/TN15LSC/TN17LSC/TN18LSC board supports latency measurement. The bidirectional latency at the ODU4 layer between two OTU boards supporting the latency measurement function can be measured, and the latency data is displayed on the U2000.

    This function is not supported when the client-side service type is OTU4.

    IEEE 1588v2Not supported
    Physical clockWhen receiving 100GE/OTU4 services on the client side, the board supports synchronous Ethernet transparent transmission instead of synchronous Ethernet processing
    Ethernet service mapping mode

    TN18LSC: Bit Transparent Mapping ODU4 and Mac Transparent Mapping ODU4.

    NOTE:
    Only the TN18LSC board supports the function.
    Electrical-layer ASONNot supported
    Optical-layer ASONSupported
    Protection scheme
    • Supports client 1+1 protection.
    • Supports intra-board 1+1 protection (when working with the OLP/DCP/QCP board).
    NOTE:

    When the client-side uses 100GBASE-SR10-100m-CFP2, 100GBASE-SR10-100 m-CFP optical module, the LSC board does not support client-side 1+1 protection.

    NOTE:
    When the client-side service is OTU4, the TN12LSC board does not support client-side 1+1 protection.
    LoopbackClient sideInloopSupported
    Outloop
    WDM sideInloopSupported
    Outloop

    Protocols or standards compliance

    Protocols or standards for transparent transmission (non-performance monitoring)

    IEEE 802.3ba

    Protocols or standards for service processing (performance monitoring)

    ITU-T G.805

    ITU-T G.806

    ITU-T G.709

    ITU-T G.872

    ITU-T G.7710

    ITU-T G.798

    ITU-T G.874

    ITU-T M.3100

    ITU-T G.874.1

    ITU-T G.875

    ITU-T G.808.1

    ITU-T G.841

    ITU-T G.8201

    ITU-T G.694.1

    ITU-T G.8261

    ITU-T G.8262

    Table 2 Functions and features of the TN18LSC board (regeneration mode)
    Function and FeatureDescription
    Basic function

    The board is used in an electrical REG station in the system to implement electrical regeneration of optical signals.

    Regenerating rate

    OTU4: OTN service at a rate of 111.81 Gbit/s

    OTN function
    • Provides the OTU4 interface on WDM-side.
    • Supports the OTN frame format and overhead processing compliant with ITU-T G.709.
    • supports the PM and TCM functions, PM and TCM non-intrusive monitoring functions.
    • Supports SM functions for OTU4.
    WDM specification

    Supports ITU-T G.694.1-compliant DWDM specifications.

    Tunable wavelength function

    The TN18LSC board can tune the optical signal output on the WDM side within the range of 96 wavelengths in extended C-band with the channel spacing of 50 GHz, and other boards can tune the optical signal output on the WDM side within the range of 80 wavelengths in the C-band with the channel spacing of 50 GHz.

    ESC functionSupported
    PRBS test function

    Not supported

    LPT function

    Not supported

    FEC coding

    The TN18LSC board supports SDFEC2 and HFEC PLUS.

    NOTE:
    Boards that use different FEC modes cannot interconnect with each other.
    Alarms and performance events monitoring
    • Monitors OTN alarms and performance events.
    • Monitors parameters such as the bias current, temperature, and optical power of the laser.
    • Supports the monitoring of CD and PMD performance.
    ALS function

    Not supported

    Test frame

    Not supported

    Electrical-layer ASON

    Not supported

    Optical-layer ASONSupported
    Protection scheme

    Not supported

    Loopback

    Not supported

    Protocol or standard compliance

    Protocols or standards (non-performance monitoring) with which transparently transmitted services comply

    -

    Protocols or standards (performance monitoring) for processing services

    ITU-T G.805

    ITU-T G.806

    ITU-T G.709

    ITU-T G.872

    ITU-T G.7710

    ITU-T G.798

    ITU-T G.874

    ITU-T M.3100

    ITU-T G.874.1

    ITU-T G.875

    ITU-T G.808.1

    ITU-T G.841

    ITU-T G.8201

    ITU-T G.694.1

    ITU-T G.8261

    ITU-T G.8262

    Mechanical Specifications

    TN12LSC
    • Dimensions of the front panel (H x W x D): 264.6 mm (10.4 in.) x 101.6 mm (4.0 in.) x 220 mm (8.7 in.)
    • Weight: 4.5 kg (9.9 lb.)
    TN13LSC
    • Dimensions of the front panel (H x W x D): 264.6 mm (10.4 in.) x 50.8 mm (2.0 in.) x 220 mm (8.7 in.)
    • Weight: 2.74 kg (6.04 lb.)
    TN15LSC
    • Dimensions of the front panel (H x W x D): 264.6 mm (10.4 in.) x 50.8 mm (2.0 in.) x 220 mm (8.7 in.)
    • Weight: 3.0 kg (6.61 lb.)
    TN17LSC
    • Dimensions of the front panel (H x W x D): 264.6 mm (10.4 in.) x 50.8 mm (2.0 in.) x 220 mm (8.7 in.)
    • Weight: 2.48 kg (5.47 lb.)
    TN18LSC
    • Dimensions of the front panel (H x W x D): 264.6 mm (10.4 in.) x 25.4 mm (1.0 in.) x 220 mm (8.7 in.)
    • Weight: 1.9 kg (4.19 lb.)

    Power Consumption

    BoardWDM-Side ModuleTypical Power Consumption (W)Maximum Power Consumptiona (W)
    TN12LSC40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN240265
    55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN255285
    TN13LSC40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN150160
    55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC)-PIN160170
    TN15LSC40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(HFEC)-PIN145.2158.5
    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM-Enhanced)-PIN174.6192.6
    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN174.6192.6
    55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN174.6192.6
    40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN174.6192.6
    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN174.6192.6

    12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDC150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PINM, Metro)-PIN

    174.6192.6
    TN17LSC

    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

    • 127 (Line mode)
    • 110.6 (regeneration mode)
    • 135 (Line mode)
    • 116 (regeneration mode)

    55000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

    40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM)-PIN

    12000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM, Metro)-PIN

    120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2)-PIN

    120000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2,wDCM)-PIN

    40000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, wDCM, LH)-PIN

    150000 ps/nm-C Band-Tunable Wavelength-ePDM-QPSK(SDFEC2, Enhanced)-PIN

    TN18LSC

    40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2, ULH+, T5U)-100G CFP

    40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2 , wDCM, LH, T62)-100G CFP

    12000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK(SDFEC2 , wDCM, Metro, T65)-100G CFP

    40000ps/nm-Extended C band-Tunable Wavelength-ePDM-QPSK (configurable FEC, coherent/wDCM, ULH+, TxA)-100G CFP

    • 71 (Line mode)
    • 62.47 (regeneration mode)
    • 78 (Line mode)
    • 72.86 (regeneration mode)
    a: The maximum power consumption is the power consumed by the board when it works normally under the highest ambient temperature.
    Delivery

    Delivery OptionsEstimated Delivery Time
    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPSOptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPSDHL3-5 business days
    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS Fedex3-5 business days
    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS By Sea10-20 business days

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPSNotice:

    Above mentioned information are just for your reference only,we will keep you posted for the tracking delivery schedule.There are two delivery options available for by air and by sea:

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPSDeliver to port:

    Uonel is responsible for transporting goods to port. All subsequent customs and transportation fees are the
    responsibility of the buyer. Uonel will recommend trustworthy local freight forwarders to you.Uonel can facilitate the progress under buyer's permission and at buyer's expense.

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPSDeliver to door:

    Uonel will quote all destination charge prior once we have confirmed order.
    Uonel is responsible for transporting goods to door after you have made the payment.

    Warranty

    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS 100% Low Price Guarantee:
    Uonel provides high-quality products at low wholesale prices


    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS 100% Quality Assurance:
    All items are ORIGINAL NEW and GENUINE only.


    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS Free Technical Support:

    Our FREE Huawei Expert Consultancy Support is over the phone, by chat, by email or by login remotely.


    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS 100% Money Back Guarantee:
    You can contact our customer service team to exchange or return any product that you bought from us.


    OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS Flexible Secure Payment & Shipment:
    Verified authorization: Mcafee Secure, VeriSign Secured

    Return Material Authorization (RMA) Process

    Standard Hardware Warranty Policy:

    Original new sealed Huawei product: 1 Year

    The Support Contacts:

    If your Huawei products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

    Company Profile

    Uonel is one of the biggest Huawei Network Hardware distributor in china, founded in 2008. We are a global provider of netwotking products with more than 5000 customers.

    We provide original new Huawei Routers,Switches,Firewalls,Wireless APs & controllers,OLTs,GPON modems,optical transceivers.Our company have more than $5million Huawei products in stock.

    Most of our technical engineers had work exprience in Huawei company,we can provide network design&planning,configration,troubleshooting,maintenance and training service in world wide.













    Quality OptiX OSN 9800 TN12LSC 100Gbit/s wavelength conversion board-- OSN9800 UPS for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Uonel Co.Limtied
    *Subject:
    *Message:
    Characters Remaining: (0/3000)